520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for glenmoore, pa


Map of Glenmoore PA
Paul W.

Paul W.


Job Checkin

Reclaimed and removed old attic system. Installed new Amana 2 stage communicating condenser on new pad and snow feet. Flushed lineset and purged with nitrogen. Brazed in with nitrogen. Installed new Amana high efficiency condensing gas furnace in new drain pan. Placed a new evaporator coil on top. Brazed in with nitrogen and installed adjustable txv. Pressure tested to 300 and evacuated to 160 microns. Raised whole supply ducting up and made a 11 inch piece to compensate. Reconnected condensate, venting, gas, and electrical. Tested gas for leaks. No leaks found. Installed ez trap and wet switch to prevent water damage. Installed April aire 213 upgrade kits in both systems. Installed Honeywell uv light system. Installed Honeywell Iaq system and red link wireless accessory. Tested system and performed combustion test. Adjusted refrigerant charge. Tested system. Everything working great at time of install.