Job Checkin

Had previously been onsite and recommended the following repairs. Returned and Installed a new Single Pole 24V Coil 40 Amp Contactor onto the Outdoor Unit. Installed a new 30/3 Mfd Dual Capacitor onto the Outdoor Unit. Removed damaged section of Thermostat Wiring Outside and ran a new Section of Wire to Outdoor Unit. Secured wiring to the Line Set. Tested operation of system upon completion. Completed AC Tune Up Checklist. Measured Refrigerant Charge on system. System is operating and cooling. The Head Pressure Is higher than normal but the Outdoor Unit is sitting directly in the sunlight which will raise the temperature of the Outdoor Unit and increase head Pressure. Also the lower efficiency of the system due to age may be attributing to the higher pressures. Due to age of system, recommend begin planning for replacement of the Gas Furnace/AC.