Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Pump down remaining refrigerant from Coil and disconnect and remove. Install a new Evaporator Coil and braze connections. Pressure test system and evacuate to below 500 Microns. Reconnect Coil Drain Piping. Add refrigerant charge to system using Subcooling/Superheat standards. Coil is covered under a Manufacturer's Parts Only Warranty until July 2022. If further leaks are found in the system we will assess the additional repairs needed. Removed old warranty coil. Installed a new amana coil On top existing furnace. Installed a new txv and brazed joints. Pressure tested and checked for leaks. Adapted drain as needed. Tested unit in cooling and charged unit as needed.