Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed heating maintenance, checked air filters ok. Cleaned burners and flame sensor, inspected heat exchangers, see rust on second floor heat exchanger but no breach. Checked voltage amperage and electrical connections, measured capacitor values. Started gas furnaces, tested limit and safety switches. Measured fuel pressures. Performed combustion test and checked temperature rise.