Checked no heat blower will not come on, found call on board for blower but no 120 volts to blower, looks like board is burnt and failed. Moved blower heat wire to 120 volt tap. Blower started and limit reset. Furnace is running at this time. Need blower control board for oil furnace. Need to follow up with owner.