520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for media, pa


Map of Media PA
Luis T.

Luis T.


Job Checkin

Install new gas furnace in existing location. Complete connections of return and supply ducting and seal all connections. Install new Flue Piping to adapt to existing Flue. Adapt Gas line and test fittings for leaks. Install new Electrical Box with outlet and switch for unit and complete electrical connections. Record Equipment and Filter Information to the system. Install new Air Filter as needed. Install new T6 Wifi Thermostat and program. Setup WiFi if he is available contacted Corey no answer Test operation and fill out form for new installation, provide instructions, and clean up work area. Ran new thermostat wire also had to run trac pipe for gas line. Talked to Corey he was unavailable to set up WiFi he will do on his own TOMORROW. 14x24x1 running up to factory standards.