No heat, tenant stated flames kept going off after seconds of startup, check furnace operation and noticed that burners ignite but after seconds it goes off, check flame rectification to ground, and reading zero, also check other electrical components, and found blower capacitor reading below it minimum rating explained findings to John the land lord and he approved the repairs, after cleaning flame sensor and performed flame rectification test and now is reading 3 micro amps, also replaced blower cap, performed combustion test and check supply and rerun air ok replaced new filter, cycle furnace ok