520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for parkesburg, pa


Map of Parkesburg PA
Luis T.

Luis T.


Job Checkin

Upon arrival found thermostat calling for heat but no flame or blower running, inducer running making high pitched sound, furnace is not working properly, after performing furnace inspection found that unit keeps going off on high limit, blower not coming on, found mother board relay not closing to bring blower, check blower operation and works ok, at this time could not performed tune up due to the furnace needing some parts, explained situation to Harry and quoted for repair customer ok repsirs and paid 50% office will get back to customer regards rerun call with new parts and come back to finished up tune up installed new inducer and fan timer also new thermostat cycle and test furnace ok also performed heat tune up, cleaned flame sensor, check manifold propane pressure ok performed combustion test ok replaced air filter, check supply and return temp ok cycle furnace ok,