Luis T.

Luis T.


Job Checkin

Performed ac tune up, found ac unit not working upon arrival, condenser fan motor not running, check electrical low and high voltage, can’t flushed drain not an opening to clean drain, check blower motor and cap, check outdoor unit found open fan capacitor, tried new cap for testing, found condenser motor getting hot more than normal, also unit is running low on refrigerant, refrigerant is no longer available, due to required repairs would recommend replacement of system, also found pressure relief valve from water heater leaking, water heater heater is from 2012. We could replace pressure relief valve or water heater replacement. Called Mary to let her know the situation but did not answer. System is from 2003 would highly recommend system upgrade.