520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Local Reviews
for plymouth meeting, pa

Rated 5.0 out of 5 stars based on 5 customer reviews

Great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Very professional and made sure everything was working well.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Good service

Arrived timely and courteous

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Brian, was on time and very knowledgeable. He was able to solve our furnace problem and explain exactly what he was doing. He was great.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

Service tech was very pleasant and professional always kind and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for plymouth meeting, pa

Brian B.

Brian B. Job Checkin

Performed heating maintenance, replaced air filter. Cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections. Started gas furnace, tested limit and safety switches. Measured fuel pressures and performed combustion test. Checked operation and temperature rise.


Brian B.

Brian B. Job Checkin

Performed heating maintenance, replaced air filter. Cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, tested limit and safety switches. Measured fuel pressures. Performed combustion test. Checked operation and temperature rise.


Brian B.

Brian B. Job Checkin

Checked condensate on duct work, found insulated duct that had condensation on it. The duct is dry but a puddle had formed when it had condensation on it. Checked dehumidifier, found drain clogged and the full bucket light was on. relative humidity is 70 %. Cleared drain and started dehumidifier.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance on 2 heat pumps, checked air filters ok. Cleaned eztraps and drains. Checked voltage, amperage and electrical connections, measured capacitor values. Started heat pumps, checked refrigerant charge and temperature drop across coils.


Barry P.

Barry P. Job Checkin

AC Tune up for 3 ton Rheem System. Replaced Filter. Drain ok. Both coils are in good condition. All electric motor s and components ok. Refrigerant pressures/subcooling/superheat ok. 28F temp split. Can mpressor Amps/indoor amps ok. Cycled system/thermostat ok. System is operating well at the time of this tune up.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, checked air filter ok. Cleaned eztrap and drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Kurt M.

Kurt M. Job Checkin

Talked to customer about problem he is having with being very dusty around the house. Talked to homeowner about air leakage and this would not cause it to be dust in the home but recommend installing a high efficiency Aprilaire filter rack system along with a reme air purifier for best performance. Duct work in basement in enclosed in drywall and is not accessible. Also recommended to get a heating and cooling membership to give discounts on these installations. Also because homeowner had mentioned tune up had not be done this year on the gas furnace.


Brian B.

Brian B. Job Checkin

Checked no backup auxiliary heat. Raised thermostat, propane furnace came on and heated. Checked air filter ok. Checked fuel pressures ok. Checked thermostat and wiring. Found no reason for no lp backup.


Chris B.

Chris B. Job Checkin

Performed Heating Tune Up on American Standard Hybrid System. Replaced High Efficiency Aprilaire 401 Air Filter. Cleaned and serviced Humidifier. Humidifier is set to 35% on Thermostat. Ran test on Humidifier from the Thermostat to test operation. Inspected Furnace and cleaned all drain lines and tubing. Cleaned Condensation Pump and EZ Trap. Tested system in Heat Pump mode and measured Air Temperatures. Tested system in Auxiliary Mode and performed Combustion Analysis on unit. Performed Precision Heating Tune Up on Heat Pump system which supplies the Sunroom Addition to the home. Checked Air Filter which was clean. Tested electrical components on Indoor and Outdoor Units. Put system into Heating mode and measured refrigerant charge. Tested Auxiliary Electric Heat and measured 20 Amps across 5kw Heating Element. Performed Inspection/Tune Up on Tankless Water Heater. Cleaned Ignitor assembly and inspected Burner Area. Checked Electrical Connections on unit. Cleaned Drain Line tubing


Brian B.

Brian B. Job Checkin

Performed heating maintenance, replaced air filter. Cleaned burners and flame sensor, inspected heat exchanger. Checked voltage, amperage and electrical connections, measured capacitor values. Started gas furnace, tested limit and safety switches. Performed combustion test. Checked operation and temperature rise.


Chris B.

Chris B. Job Checkin

Performed precision Heating tun up on Amana gas Furnace. Replaced 20x25x1 air filter. Inspected Irving nd components. Cleaned Pressure switch tubing and inducer Orifice. Cleaned flame sensor and inspected burners and heat exchanger. Put system into operation and performed combustion analysis. System operating to standards upon completion.


Brian B.

Brian B. Job Checkin

Performed cooling maintenance, checked media air filter. Blew out condensate drain. Checked voltage, amperage and electrical connections, measured capacitor values. Started air conditioner, checked refrigerant charge and temperature drop across coil.


Kurt M.

Kurt M. Job Checkin

Performed precision a/c tune up on older York a/c system. 16x25x1 air filter was just replaced. Checked all electrical conections and components. Blew out condensate drain. Found fins on outside coil very beat up and not in the best of shape. Checked temperature split at indoor unit. Checked refrigerant pressures and temperatures at indoor and outdoor units. System is working ok but would recommend to start thinking about replacement of system. Homeowner had also mentioned that he wanted a price to install a high efficiency filter rack system. Gave homeowner a quote to install.


Brian B.

Brian B. Job Checkin

Performed 6 month quality check on new system, checked furnace setup, checked media air filter. Tested water safety. Started heat pump, checked refrigerant charge. Checked operation and temperature drop across coil. Serviced sunroom unit, checked air filter, cleaned condensate trap and drain. Checked voltage, amperage and electrical connections, measured capacitor values ok. Started heat pump, checked refrigerant charge and temperature drop across coil.


Kurt M.

Kurt M. Job Checkin

Performed a/c tune up on amana a/c system. 20x25x1 air filter is clean. Blew out condensate drain. Checked all electrical conections and components. Tested condensate pump. Checked refrigerant pressures and temperatures at indoor and outdoor units. System is working fine at time of inspection.