520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for plymouth meeting, pa


Map of Plymouth Meeting PA
Kurt M.

Kurt M.


Job Checkin

When I arrived found thermostat room temperature at 57 degrees and set point at 80 degrees on cooling setting. Switched over to heating and furnace went thru sequence of operation, fired up then locked out on pressure switch error code.cleaqned Daly’s out of trap, and made sure all tubing was open . Turned on furnace and still had a pressure switch error code. Took off exahaust pipe and found 2” pvc half way full of flys and fly larva. Dumped out pipe and furnace continued to run smoothly. Only on the thing I noticed was the counter balance for the inducer motor was brittle and was starting to break off. For now homeowner is going to leave alone .