Job Checkin

Returned to site to install a Wireless Outdoor Sensor for the Hybrid System. Connected Sensor to the Prestige IAQ Thermostat. Mounted Sensor on wall near the Outdoor Disconnect Box. Setup set points on Thermostat Programming. System is setup to Lockout the Heat Pump at or below 40 Degrees. Reviewed all settings on Thermostat and adjusted Humidifier Control to be operated by the Thermostat. This will allow the Thermostat to turn the Humidifier and Blower Fan on in between Heating Cycles if the Humidity falls below 35%. Put system in operation to test.