Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
2/1/22: No heat Service call: 100KBTU Amana Natural gas communicating furnace. Allowed furnace to attempt trial for ignition/ made call for heat at thermostat. Trial for ignition stopped when gas valve should have opened. While checking for 24V at the gas valve molex plug, found that the molex plug itself was not tight. Board was giving 24V at appropriate time. After securing molex plug, furnace operated as designed. Checked temp rise, checked wiring, made sure all wiring connections were sound, uploaded available CoolCloud updates. Verified that there were no communication errors (system is fully communicating including outdoor AC). Verified flame sense/rectification circuit. Furnace is operating well at the time of this service.