Job Checkin

Install OEM heat kit with capacity to support the building load and complete all wiring connections. Setup backup heat setup on unit and thermostat as needed. Test operation of heat kit and measure air temperature rise. 2/16/21 Installed and wired strip heater. Verified low voltage wiring. Set dip switches on air handler. Programmed lyric thermostat and cycled strip heater. Temp Rise 25F at supply grille. Amp draw 42 amps.