Service call that the Humdifier was leaking. Humidifier was turned off upon arrival. Turned Humidifier on and tested. Found Humidifier Panel was corroded and water was leaking over the top of the tray. Humidifier was cleaned and serviced in December. Hard water could cause the Water Panel to corrode prematurely. Cleaned Humidifier Tray and replaced Water Panel. Blew through Drain Tubing to ensure it was clear. Turned Humidifier back on and monitored. Allowed Humidifier to run for 10-15 minutes and found no signs of Water Leaking. If was leak occurs again, recommend replacement of the Water Panel Tray and Feeder Tube. If the Feeder tube cannot sit in the proper position on the top of the tray is it can cause water issues. Included an estimate for the Water Panel Tray and Feeder Tube for an Aprilaire 500 Humidifier.