Service call that the Gas Furnace was not running. Upon arrival turned system on to test operation. Found system was lighting and then shutting down within 1-2 Seconds. Checked Amps across Flame Sensor. Measured Gas Pressure on system. Checked all safety switches on system and measured Pressure across the Inducer Motor Pressure Switch. System was intermittently lighting and running. Control Module on Furnace is working intermittently and shutting system down. Due to age of system would recommend replacement of the Gas Furnace and AC rather than repairing. The system is about 24 Years old and the AC system has a known refrigerant leak from before. While the system is operating now, it may continue to have issues. Due to the age, and issues with both the AC and Gas Furnace system replacement is recommended. We would have to call manufacturer to get pricing for a new Control Board. We will follow up with a quote for the replacement of the system.