Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Performed gas heat tune up, check electrical low and high, replaced filter, flushed drain test pump ok, cleaned flame sensor, ad check burners, found igniter with some wear, it about 70% life, would recommend replacement, emailed proposal for igniter replacement, service humidifier test and set to 35% winter, check low and high stages combustion test ok cycle unit