When we arrived went to the basement and found that water had leaked and had soaked some of the carpet in the basement. After talking to customer, son had been running the air conditioning on a cold day which may have cause ice build up at indoor coil. Also found that 115 volt condensation pump was not working, tested with water. They also have an exsisting older Aprilaire humidifier above pump where the previous homeowner must have removed the water drain to the humidifier, this could have also caused the water leak. Put wire nuts on wires that were going to the solenoid so humidifier does not come on. Gave customer a quote to replace exsisting humidifier with new Aprilaire 600m humidifier. Also gave them a quote to remove it all together and patch metal return duct with a piece of sheet metal. For the time being replaced faulty 115 volt condensation pump and tested , pump is working fine at time of service.