520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.


Job Locations
for wayne, pa


Map of Wayne PA
Kurt M.

Kurt M.


Job Checkin

Found that after checking out the de-humidifier was functioning correctly. Washed off wasable filter again. Found de-humidifier set at 40%. Found humidity inside the home was reading 55% on Ecobee thermostat on first floor. Down in crawl space at the de-humidifier unit it was reading 43 %. Checked the humidity with a psycrometer. Was reading 52%. Found that at the air handler in garage the filter box was not completely sealed. Tapped around filter door to not pull humidity from the garage. Recommend to homeowner that if he really wants to help with the humidity levels during the summer months a new heat pump with variable speed blower and 2 stage compressor would help with reducing humidity levels in side the home. Homeowner is not ready to replace the system at this time. Recommend he keep his thermostat set at 70 degrees for a/c to run more often. Also a return was removed by a previous contractor.