Checked no cooling complaint, indoor coil iced up, checked coil it’s free of ice, checked air filter ok. Started air conditioner, checked blower on, checked refrigerant charge, found low on charge. Topped off refrigerant charge, balanced by superheat, checked operation and temperature drop across coil Can’t guaranty charge there is a leak. Recommend replacing air conditioner.