No heat, found thermostat calling for heat upon arrival, found voltage to unit, high and low, no display on led light indicator, check back side of control board and noticed water hot in contact with board, also can see secondary heat exchanger cover is leaking making its way to board, board need to replaced so we can test heater... Replace control module and sealed secondary heat exchanger reservoir After installing control board and sealed collector box cycle and test furnace couple times ok, performed combustion test and cleaned sensor and check burners ok manifold gas pressure ok test pump ok cycle heater ok while testing furnace noticed water heater would not light and goes into soft lock out informed customer about situation and recommended replacing water heater average life is 10 years and it is 9 years emailed proposal for new water heater