520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.


Job Locations
for west bradford township, pa


Map of West Bradford Township PA
Chris B.

Chris B.


Job Checkin

Service call that the Oil Furnace was not running. Found Primary Control out on Lockout. Reset the Controller and tested system. Found Burners running but locking out due to no ignition. Bled oil line to test flow and found Air in Oil Lines. Removed Oil Filter and Pump Strainer. Checked Oil Nozzle and electrode positioning. Put system back in operation and bled lines of Air. Cycled system and monitored to insure it was lighting. Even with system running, small amounts of Air are present in the Oil Line. If system goes out on Lockout agin due to Air being in the Line, we will need to install a Tiger Loop system which will help bleed the Air out. System is a single pipe system and is running above the Tank along the Ductwork/Ceiling. This could be causing the Air Pockets to form in Oil Line.