Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Returned to site to charge system. Put system in operation and added 2lbs of R-22 Refrigerant to system, charging by Superheat standards. Charged system to recommended superheat of 22 Degrees. Supply temperature was 61 and return temperature was 81 after adding refrigerant. Office will contact on Monday to verify installation date/time.