Have any feedback for us? We'd love to hear it! Call us at (610) 595-9072 and let us know how we are doing.
Installed t10 smart thermostat with room sensor, and service plan. Heat tune up for 80K BTU single stage Luxaire propane furnace. Cleaned flame sensor. HSI Ohms 45; ok. Adjusted gas pressure from 8.89†WC to 10â€WC. Temp rise Heat Pump 16F; temp rise furnace 53. All electric motors and components ok. Combustion test ok. Furnace is working well at the time of this maintenance/tune up.