520 Trestle Place
Downingtown, PA 19335
(610) 873-1244

Job Locations
for west grove, pa


Map of West Grove PA
Luis T.

Luis T.


Job Checkin

Installed t10 smart thermostat with room sensor, and service plan. Heat tune up for 80K BTU single stage Luxaire propane furnace. Cleaned flame sensor. HSI Ohms 45; ok. Adjusted gas pressure from 8.89” WC to 10”WC. Temp rise Heat Pump 16F; temp rise furnace 53. All electric motors and components ok. Combustion test ok. Furnace is working well at the time of this maintenance/tune up.