Victor came and spent some time troubleshooting my heater unit. He finally diagnosed the problem as an unreliable pressure switch. His approach to troubleshooting was thorough and logical.
Heating system serviced and checked for proper operations on the Trane roof top equipment. Presented repair recommendations to the customer.
Lennox heater is not working properly. Began troubleshooting and found a failed pressure switch for the safety circuit. Presented options and made the necessary repairs. The heating repairs are complete.
Service call for an air conditioner that is not working. Trane air conditioner did not come on in the cool mode as set on the thermostat. Found melted wiring and a failed run capacitor. Replaced the parts and replaced all failed wiring. The current status is normal. The air conditioner is now working and the air conditioner repair is complete.
Existing customer in Pkeasanton had a maintenance service performed on the air conditioner.
Performed a maintenance service for commercial equipment on a rooftop. The two York units were serviced checked and maintained. Filters were replaced air temperature was checked belts and cleaning was performed. Reviewed with customer and took supplier temperature readings.
Commercial air conditioners field and the customer like us to take a look at the cooling cycle. Arrived on site checked out system found a failed indoor fan motor. Will need to order parts received approval.
Performed a maintenance service for a commercial equipment in Pleasanton surgery center. Right on site checked all systems are cooling side replace filters check belts motors Compressors and make sure everything was working Perspex submitted proposals for repairs and met with customer. The performing equipment is working and the building is maintaining temperature.
Performed repair on concord air conditioning equipment. Changed all filters and inspected all electrical connections and terminals. Cycled unit in the cool mode to ensure proper operation. Current system status normal at this time.
A Yorky heating and air-conditioning system in a commercial building was just serviced. Make sure all components and system is functioning properly. Found a first stage compressor on the main unit flat on charge. Your customer options to make the repairs. Will return to take care of the system and bring it to normal working conditions.
Maintenance service on a residential roof top package unit- Tempstar brand. Serviced the furnace side of the unit and tested the heating system. Reset the thermostat and replaced the batteries.
Maintenance service on a residential roof top package unit- Tempstar brand. Serviced the furnace side of the unit and tested the heating system. Reset the thermostat and replaced the batteries.
Service call no heating, several furnace heaters were not working properly, recommended repairs to the units. Repaired some wiring and replaced a igniter and cleaned out the pressure tubing. Set the thermostats for heat and will propose further repairs.
Service call no heating in the home, found the main control board not bringing on the heater, removed and replaced and wired the new control board into place, tested the heater and reset the thermostat.
Service call no heat, found a failed igniter after some troubleshooting. Removed and replaced and tested the heater and set up the thermostat.
Service call no heating, found a failed igniter. Removed and replaced the igniter, tested the heater and cycled in heating at the thermostat.