Work Performed Responded to complaint of water leaking from 1-year-old ductless system Inspected indoor unit and traced issue to the condensate drain line Found that the drain line was not properly connected to the PVC piping Disassembled the line hide outside and found a spiderweb clog near where the drain exits the wall Cleared the blockage and reconnected the drain using Gorilla tubing Secured the line to drain properly down to the outdoor unit This setup helps prevent insects from entering and clogging the line in areas that are hard to access Results Drain line is now clear and properly connected No more leaking from the indoor unit System is operating normally at this time