850 U.S. 9
Fishkill, NY 12524
845-896-4328

Job Locations
for highland, ny


Map of Highland NY
Chris H.

Chris H.


Job Checkin

Found broken wire going from gas valve to temperature sensor breaking voltage to gas valve causing system to not light, re connected wires and re lit pilot and system fired right up, let run for 20 minutes no error codes at propane gas valve and customer should have hot water in 45 minutes.