Installed Amana furnace with evaporator coil and condenser, exhaust and fresh air piped outside in 3†pvc pipe, new plenum and 16x25 media filter. Furnace converted to LP, started ac, didn’t start heat, gas pipe not done yet ( by homeowner) installed T6 thermostat and condensate pump.