850 U.S. 9
Fishkill, NY 12524
845-896-4328

Local Reviews
for wappingers falls, ny

Rated 4.9 out of 5 stars based on 234 customer reviews

Central air replacement

Reputable and professional. Glad I chose them to do the job.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Best service provider in Hudson Valley

Above and beyond expectations with professional, knowledgeable and friendly service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Excellent work

Very pleased

  • Overall Experience
  • Quality
  • Price
  • Convenience

Noah provides great service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very satisfied

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great job

Very nice person and efficient worker

  • Overall Experience
  • Quality
  • Price
  • Convenience

Repair Leak on Heating Pipe near air handler

  • Overall Experience
  • Quality
  • Price
  • Convenience

Thank you. Have air!!

Would highly recommend Folkes

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great

Thanks for fixing the problem so quickly, he was professional and informative

  • Overall Experience
  • Quality
  • Price
  • Convenience

Reliable and Professional Service

Our tech was very professional and completed the work perfectly!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for wappingers falls, ny

Tyler F.

Tyler F. Job Checkin

Arrived at customers house for a mainline backup. After evaluating found that the customers main line needed to be cabled. Was able to clear mainline and camera it. Found a small dip in pipe and grease had compromised it as well causing backup. Advised customer that the mainline will backup again and a permanent solution should be done stop problem. Gave customer estimates.


Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

Replaced zone panel and now both zones and thermostat have power going to them. Did notice coil was froze will have to let thaw out and return either Tuesday or Wednesday to recheck system. System off at thermostats.


Scott Y.

Scott Y. Job Checkin

Found clogged drain. Cleared drain, tested with bottle of water, system draining. System operating normally.


Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

Drain pan not draining properly. Pan slightly sloped due to missing strew in back, leveled pan and put new trap in ran water bottle through pan and saw water coming from other end of pipe. Emergency pan is very warped.


tonyp@folkeshomeservices.com

tonyp@folkeshomeservices.com Job Checkin

Completed annual ac tune up on one ductless ac system. Cleaned filters. Brushed and sprayed both coils. Took temperatures and pressures. Blower wheel is clean. No signs of mold growth yet.


Margaret M.

Margaret M. Job Checkin

1 gas & 1 A/C renew


Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

First floor working but basement zone not coming on when put by itself, jumped wires at thermostat and condenser still didn’t come on. Checked voltage to zone panel and was only getting 11 volts for basement zone. Will need a new zone panel.


Greg M.

Greg M. Job Checkin

Checked over operation of both ac systems. Customer stated that right event room not maintaining temperature. Temperature set for 71, only maintaining 74. Checked system running pressures and temperatures, zoning, filters, coils. Everything working normally at this time. System seems to be undersized for area it’s conditioning. There is a large ductless unit for area for most likely this reason. Recommended to use ductless unit on warmer days to supplement central air.


Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

Performed AC tune up on two systems, changed return filters, cleared condensate traps, cleaned inside coils, tested blower wheel capacitors. At condenser for second floor tested pressures which were normal, capacitor tested in range. First floor condenser not running when calling for AC noticed mice chewed fan and condenser wire and capacitor was dead, fixed wiring installed in capacitor, and tested pressures are normal, both systems are operational.


Noah  D.

Noah D. Job Checkin

Installed new water heater and tested system.


Chrish@folkeshomeservices.com

Chrish@folkeshomeservices.com Job Checkin

Water heater is 57 inches tall 40 gallon natural gas. need to order water heater for install took half payment for deposit.


tonyp@folkeshomeservices.com

tonyp@folkeshomeservices.com Job Checkin

Found pvc drain pipe popped out of pump. Corrected pvc. Tested pump operation. No further issues to report.


Tyler F.

Tyler F. Job Checkin

Arrived at customers house for a 93 or free branch line . Found the kitchen sink draining slowly. Sent cable machine through line an it cleared up. Tested and checked for leaks. All is good at this time


tonyp@folkeshomeservices.com

tonyp@folkeshomeservices.com Job Checkin

Completed annual ac tune up on one system. Found male adapter for condensate drain line from evap coil pan leaking. Replaced male adapter. Poured 5 gallons of water throughout pan. Tested operation and leak has been resolved. Also cleared condensate line. Condensate line was backed up. Took temperatures and pressures. Delta t is 21 degrees. Supply temperature is 49 degrees and return temperature is 70 degrees. Both coils were brushed clean. No further issues to report at this time. Customer advised of r-22 phase out.


Tyler F.

Tyler F. Job Checkin

Arrived at customer house for possible recall. Found that the outside Spicket was loose due to pour re-installation of concrete. Removed the concrete and resealed.