7510 Lannon Ave
Otsego, MN 55301
7635156411

Local Reviews
for zimmerman, mn


Job Locations
for zimmerman, mn

Jay R.

Jay R. Job Checkin

Furnace repair. Customer has a 10year old janitrol furnace. Model GMNT100-4. Furnace will not light. Install a new hot surface ignitor. If your furnace will not light. Call for service today.

Furnace repair. Customer has a 10year old janitrol furnace. Model GMNT100-4. Furnace will not light. Install a new hot surface ignitor. If your furnace will not light. Call for service today.

Jay R.

Jay R. Job Checkin

Furnace repair call. Customer has a 8 year old Payne furnace. Model PG9MAB048080. Furnace is making a very loud noise when running. Install a new inducer fan, and motor. If your furnace is not working. Call us today.

Furnace repair call. Customer has a 8 year old Payne furnace. Model PG9MAB048080. Furnace is making a very loud noise when running. Install a new inducer fan, and motor. If your furnace is not working. Call us today.

Jay R.

Jay R. Job Checkin

Furnace repair call. 5 year old Rheem classic plus furnace. Model RGPQ-07EAMER. Furnace is very dirty. Combustion sensor is bad. Blower motor showing wear. Replace combustion sensor. Clean furnace. Perform tune up. Replace blower motor. If you have a 5 year of furnace have your system tune up. To help prevent break downs.

Furnace repair call. 5 year old Rheem classic plus furnace. Model RGPQ-07EAMER. Furnace is very dirty. Combustion sensor is bad. Blower motor showing wear. Replace combustion sensor. Clean furnace. Perform tune up. Replace blower motor. If you have a 5 year of furnace have your system tune up. To help prevent break downs.

Jay R.

Jay R. Job Checkin

Air conditioner repair call. York ac not cooling. 30 year old system. Compressor is bad. Gave options to replace with a goodman air conditioner.

Air conditioner repair call. York ac not cooling. 30 year old system. Compressor is bad. Gave options to replace with a goodman air conditioner.