Job Checkin

Inspected all Performance, Mechanical and Safety Systems. Upon inspection of system, I found that the refrigerant levels were not stabilized with the system turned off. Reset complete HVAC system and found the refrigerant metering device has failed. Presented my findings to the client and we have decided to move forward with replacement of the metering device. Part has been ordered and our office will contact the client to schedule once received. Removed failed metering device, installed new inline refrigerant filter, new metering device and pressure tested system to verify no leaks present. Pulled deep vacuum. Reset the HVAC system, started up and recharged system back to manufacture’s specifications for operation. Everything is working at this time.