Job Checkin

Performed service diagnostic. Diagnostic found that the drain tube from the condensate drain pump had been disconnected. Tube was sitting underneath an animal trap that had been placed in the attic by the pest control company. Further investigation found a partial clog in the condensate drain line, and water had backed up into the secondary drain pan. Options for repair were presented to customer. Customer chose to the have the drain line cleared and the water removed. Drain line was cleared and treated. Water was removed from the secondary drain pan. Tube from the condensate pump was reattached to the drain line. Condensate drain pump was tested for function. System was running at the time of departure.