We had an entire coal furnace and old propane furnace removed. Then had an entire new energy efficient furnace, air conditioning, filter system and heat pump installed. The guys did a tremendous job! Showed up on time, very pleasant and courteous. Cleaned up after the job was done. Explained the system and answered all our questions. We would highly recommend Gary & Sons to anyone!
Response from Gary & Sons, Inc.:
Thank you for your kind review! We are always happy to hear that our customers are happy!
I will recommend Gary and Sons to my friends. The service was great and I was pleased with the $$$
Response from Gary & Sons, Inc.:
Thank you for the recommendations! We appreciate it!
Very pleased with their knowledge, and good manners.
Response from Gary & Sons, Inc.:
Thank you for allowing us to provide you 5-star HVAC maintenance and repair. We look forward to working with you again in the future!
Lucas and Jake did an outstanding job. They were very professional. Very neat job.
Response from Gary & Sons, Inc.:
Gary & Son's was happy to provide you top rated HVAC service & repair. Thank you!
Your service tech was very kind and explained everything. Cleaned up afterwards. Thank you.
I had a problem, one phone call and they were out the next day. Great price too. I was worried because you kinda need heat in March and the cost was a huge concern. Problem was fixed and very affordable.
Quick response Professionals from start to finish
Our furnace went out and after calling multiple companies, Gary & Sons was the only one willing to come look at it in a timely manner. They had a new furnace installed for us within a couple days which was much appreciated especially in the dead of winter. They were on time, professional, and cleaned up after the job was done. Will definitely recommend them to friends and family!
Drake was respectful, courteous and knowledgeable about his job.
Unit operating with cover removed, unit kept defaulting to trap filling mode and when coming out of it it would turn system off like there was no call for heat and supply temperature would quickly increase with pumps on and no flame ramping up then default back to trap filling. Could be a glitch in the control due to being cold or it could be sporadically failing. Determine EA code to possibly be from ignitor leaking and recirculation in boiler cabinet. Combustion motor sounds like it's on its way out as well. Changed ignitor system was running fine without cover and with it on now. Recommend PSA
Cut coupler out and replaced with 3/4" union. Soap tested it and the surrounding fittings
On cleaned and service I found a cracked heat exchanger on high efficiency everrest furnace.
PLANNED SERVICE AGREEMENT/ MAINTENANCE, A/C EQUIPMENT