knowledgable technician

Technitian was fast to trouble shoot. Expensive service but good one.


Response from Go Green Express Home Services:

Dear Miraz, Thank you for taking the time to give a 5 Star Rating! We appreciate it. We are happy to read that Phil was knowledgeable and fast to trouble shoot. Thanks again for using Go Green Express Home Services.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for woodstock, ny

Miguel  C.

Miguel C. Job Checkin

LUICAR & MIGCOL Arrived to perform leak search and chemical cleanings, Customer paid 50% deposit via credit card $2993.60, Upon work completion collect $2993.61, performed evacuation and nitrogen leak search for one outdoor unit and three indoor units, installed new flare (by condenser) for master bedroom unit, no leaks at this time, performed three indoor unit chemical cleanings, performed secondary leak search using electronic leak detector, found small leak in Schrader valve (by condenser) for living room unit, tightened Schrader valve, leak stopped, observed system operation, ac operating ok at this time, customer paid via check#1032 Note : master bedroom indoor unit making modulation noise and not ramping up as much as the other Two units, took temp readings, 58F supply 83F return, further diagnostic will be performed, callback when supply house is open, current time (6pm)


Miguel  C.

Miguel C. Job Checkin

LUICAR & MIGCOL Arrived to perform leak search and chemical cleanings, Customer paid 50% deposit via credit card $2993.60, Upon work completion collect $2993.61, performed evacuation and nitrogen leak search for one outdoor unit and three indoor units, installed new flare (by condenser) for master bedroom unit, no leaks at this time, performed three indoor unit chemical cleanings, performed secondary leak search using electronic leak detector, found small leak in Schrader valve (by condenser) for living room unit, tightened Schrader valve, leak stopped, observed system operation, ac operating ok at this time, customer paid via check#1032 Note : master bedroom indoor unit making modulation noise and not ramping up as much as the other Two units, took temp readings, 58F supply 83F return, further diagnostic will be performed, callback when supply house is open, current time (6pm)


Miguel  C.

Miguel C. Job Checkin

LUICAR & MIGCOL Arrived to perform leak search and chemical cleanings, Customer paid 50% deposit via credit card $2993.60, Upon work completion collect $2993.61, performed evacuation and nitrogen leak search for one outdoor unit and three indoor units, installed new flare (by condenser) for master bedroom unit, no leaks at this time, performed three indoor unit chemical cleanings, performed secondary leak search using electronic leak detector, found small leak in Schrader valve (by condenser) for living room unit, tightened Schrader valve, leak stopped, observed system operation, ac operating ok at this time, customer paid via check#1032 Note : master bedroom indoor unit making modulation noise and not ramping up as much as the other Two units, took temp readings, 58F supply 83F return, further diagnostic will be performed, callback when supply house is open, current time (6pm)


Miguel  C.

Miguel C. Job Checkin

LUICAR & MIGCOL Arrived to perform leak search and chemical cleanings, Customer paid 50% deposit via credit card $2993.60, Upon work completion collect $2993.61, performed evacuation and nitrogen leak search for one outdoor unit and three indoor units, installed new flare (by condenser) for master bedroom unit, no leaks at this time, performed three indoor unit chemical cleanings, performed secondary leak search using electronic leak detector, found small leak in Schrader valve (by condenser) for living room unit, tightened Schrader valve, leak stopped, observed system operation, ac operating ok at this time, customer paid via check#1032 Note : master bedroom indoor unit making modulation noise and not ramping up as much as the other Two units, took temp readings, 58F supply 83F return, further diagnostic will be performed, callback when supply house is open, current time (6pm)


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, customer approved and signed trip and diagnostic fees, performed diagnostics, (1) Fujitsu ductless system has three indoor units, only one indoor unit cools ok at a time, indoor units have heavy signs of debris and bacteria build up, presented estimates, customer will review options, collect trip and diagnostic via check


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, customer approved and signed trip and diagnostic fees, performed diagnostics, (1) Fujitsu ductless system has three indoor units, only one indoor unit cools ok at a time, indoor units have heavy signs of debris and bacteria build up, presented estimates, customer will review options, collect trip and diagnostic via check


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, customer approved and signed trip and diagnostic fees, performed diagnostics, (1) Fujitsu ductless system has three indoor units, only one indoor unit cools ok at a time, indoor units have heavy signs of debris and bacteria build up, presented estimates, customer will review options, collect trip and diagnostic via check


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, customer approved and signed trip and diagnostic fees, performed diagnostics, (1) Fujitsu ductless system has three indoor units, only one indoor unit cools ok at a time, indoor units have heavy signs of debris and bacteria build up, presented estimates, customer will review options, collect trip and diagnostic via check


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, Presented $99 trip plus $120 minimum diagnostic fee, Customer approved and signed fees, performed diagnostic for three indoor ductless units and one outdoor unit, found heavy signs of bacteria build up, took temperature readings, diagnostics indicating system is low on refrigerant charge, presented recommendations, customer will review options, customer paid trip, diagnostic and first month ac partner plan via credit card


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, Presented $99 trip plus $120 minimum diagnostic fee, Customer approved and signed fees, performed diagnostic for three indoor ductless units and one outdoor unit, found heavy signs of bacteria build up, took temperature readings, diagnostics indicating system is low on refrigerant charge, presented recommendations, customer will review options, customer paid trip, diagnostic and first month ac partner plan via credit card


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, Presented $99 trip plus $120 minimum diagnostic fee, Customer approved and signed fees, performed diagnostic for three indoor ductless units and one outdoor unit, found heavy signs of bacteria build up, took temperature readings, diagnostics indicating system is low on refrigerant charge, presented recommendations, customer will review options, customer paid trip, diagnostic and first month ac partner plan via credit card


Miguel  C.

Miguel C. Job Checkin

Arrived to perform ac diagnostics, Presented $99 trip plus $120 minimum diagnostic fee, Customer approved and signed fees, performed diagnostic for three indoor ductless units and one outdoor unit, found heavy signs of bacteria build up, took temperature readings, diagnostics indicating system is low on refrigerant charge, presented recommendations, customer will review options, customer paid trip, diagnostic and first month ac partner plan via credit card


Philip G.

Philip G. Job Checkin

Ac not working properly


Kimberly S.

Kimberly S. Job Checkin

AC estimate


Hilary V.

Hilary V. Job Checkin

Oil Boiler Preventative Maintenance Inspection