7243 Sawmill Rd, Ste 205B
Dublin, OH 43016
(614) 490-7520

Local Reviews
for groveport, oh

Rated 5.0 out of 5 stars based on 1 customer reviews

Great service, good prices awesome staff

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for groveport, oh

Lucas M.

Lucas M. Job Checkin

Upon arrival I completed a Half Install of a Carrier 96% Two-Stage Gas Furnace 59TP6 (Up to 100,000 BTU) The system is operational upon departure.

Upon arrival I completed a Half Install of a Carrier 96% Two-Stage Gas Furnace 59TP6 (Up to 100,000 BTU) The system is operational upon departure.

Lucas M.

Lucas M. Job Checkin

I installed a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for cooling season.

I installed a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for cooling season.

Lucas M.

Lucas M. Job Checkin

I installed a Carrier 15 SEER 3 Ton Heat Pump. System is set and customer is ready for the cooling season.

I installed a Carrier 15 SEER 3 Ton Heat Pump. System is set and customer is ready for the cooling season.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for the cooling season.

I installed a Carrier 80% 70,000 BTU Gas Furnace and a Five Star 13 SEER 2.5 Ton Air Conditioner. System is set and customer is ready for the cooling season.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 96% 60,000 BTU Gas Furnace

I installed a Carrier 96% 60,000 BTU Gas Furnace

Adam  S.

Adam S. Job Checkin

I installed a Carrier 40k btu furnace and a Carrier 13 SEER 2 Ton Air Conditioner

I installed a Carrier 40k btu furnace and a Carrier 13 SEER 2 Ton Air Conditioner

Lucas M.

Lucas M. Job Checkin

Installed Five Star 80% 45,000 BTU Gas Furnace.

Installed Five Star 80% 45,000 BTU Gas Furnace.

Isaiah C.

Isaiah C. Job Checkin

I am Performing our Five Star Tune-Up & Safety Check on a 2017 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

	I am Performing our Five Star Tune-Up & Safety Check on a  2017 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Isaiah C.

Isaiah C. Job Checkin

Performing our Five Star Tune-Up & Safety Check on a 2000 Bryant . All readings were within manufacturer's specifications, unit operating properly at this time.

Performing our Five Star Tune-Up & Safety Check on a 2000 Bryant  . All readings were within manufacturer's specifications, unit operating properly at this time.

Justin M.

Justin M. Job Checkin

Found Carrier AC low on refrigerant during tuneup. Customer declined adding refrigerant at this time.

Found Carrier AC low on refrigerant during tuneup. Customer declined adding refrigerant at this time.

Justin M.

Justin M. Job Checkin

Installed New blower motor. Heat and cooling came back on. Might have a bad TXV. Returning to re-diagnose system.

Installed New blower motor. Heat and cooling came back on. Might have a bad TXV. Returning to re-diagnose system.

Justin M.

Justin M. Job Checkin

Diagnostic Service Call on 7 year old Bryant unit. Blower motor does not come on. Cabinet is rusty and is damaged from water Drain line is clogged and slopped incorrectly, causing pan to overfill and leak onto motor Hooked up motor from truck and it started. Ordered blower motor and will schedule as soon as possible

Diagnostic Service Call on 7 year old Bryant unit. Blower motor does not come on. Cabinet is rusty and is damaged from water Drain line is clogged and slopped incorrectly, causing pan to overfill and leak onto motor Hooked up motor from truck and it started. Ordered blower motor and will schedule as soon as possible

Haidar H.

Haidar H. Job Checkin

Maintenance has changed the coil already, but still leaking 410A. Advised maintenance that management would need to approve the leak test. Leak can also possibly be in the ground where the line set runs. Have to test the new coil and condenser.


Haidar H.

Haidar H. Job Checkin

Maintenance has changed the coil already, but still leaking 410A. Advised maintenance that management would need to approve the leak test. Leak can also possibly be in the ground where the line set runs. Have to test the new coil and condenser.


Haidar H.

Haidar H. Job Checkin

Maintenance has changed the coil already, but still leaking 410A. Advised maintenance that management would need to approve the leak test. Leak can also possibly be in the ground where the line set runs. Have to test the new coil and condenser.