Lucas M.

Lucas M. Job Checkin

I completed a Full Install of a Carrier 80% Gas Furnace 58SBO (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Carrier 13 SEER Air Conditioner 24ABB3 (Up to 3 ton). The system is operational upon departure.


Lucas M.

Lucas M. Job Checkin

I completed a Full Install of a Carrier 96% Two-Stage 80,000 BTU Gas Furnace. Carrier 16 SEER 3.5 Ton Heat Pump. The system is operational upon departure.


Lucas M.

Lucas M. Job Checkin

I completed a Half Install of Carrier 13 SEER 2.5 Ton Air Conditioner. The system is operational upon departure.

I completed a Half Install of Carrier 13 SEER 2.5 Ton Air Conditioner. The system is operational upon departure.

Adam  S.

Adam S. Job Checkin

I completed a Full Install of a Carrier 80% Gas Furnace 58SBO (Up to 100,000BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Carrier 13 SEER Air Conditioner 24ABB3 (Up to 3 ton) The system is operational upon departure.


Lucas M.

Lucas M. Job Checkin

I completed a Full Install of Carrier 96% Gas Furnace 59SC5 (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U Carrier 16 SEER Air Conditioner 24ABC6 (Up to 3 ton)

I completed a Full Install of Carrier 96% Gas Furnace 59SC5 (Up to 100,000 BTU) Honeywell T6 Programmable Thermostat/Emerson 1F85U
Carrier 16 SEER Air Conditioner 24ABC6 (Up to 3 ton)

Lucas M.

Lucas M. Job Checkin

I completed Scheduled Maintenance Agreement Renewal for an existing customer. What is Included in an SMA (Scheduled Maintenance Agreement? 1-Cooling Tune-Up 1-Heating Tune-Up Customer to receive PRIORITY SERVICE 50% Off Normal, After Hours or Holiday Diagnostic 10% Off All repairs 10% Off Any Indoor Air Quality Equipment


Lucas M.

Lucas M. Job Checkin

I completed an install on a Carrier 13 SEER 2.5 Ton Air Conditioner. Customer did not have A/C upon arrival. System fully functional at the time of departure.

I completed an install on a Carrier 13 SEER 2.5 Ton Air Conditioner. Customer did not have A/C upon arrival. System fully functional at the time of departure.

Lucas M.

Lucas M. Job Checkin

I installed a Five Star 95% 60,000 BTU Gas Furnace 3.5T 17. I cycled the system to ensure functionality. System is operational upon departure.

I installed a Five Star 95% 60,000 BTU Gas Furnace 3.5T 17. I cycled the system to ensure functionality. System is operational upon departure.

Lucas M.

Lucas M. Job Checkin

I installed a Carrier 13 SEER 3 Ton Air Conditioner and installed duct work to provide heating and cooling to unheated/cooled rooms and moved the thermostat to be more centrally located.

I installed a Carrier 13 SEER 3 Ton Air Conditioner and installed duct work to provide heating and cooling to unheated/cooled rooms and moved the thermostat to be more centrally located.

Isaiah C.

Isaiah C. Job Checkin

When I arrived, I saw the heat pump still had ice on it. I was able to chip enough away to replace the defrost sensor. I advised the customer we would need to wait for the system to fully thaw before running it and making sure everything was working. System not operational due to the heat pump still having ice build up.

When I arrived, I saw the heat pump still had ice on it. I was able to chip enough away to replace the defrost sensor. I advised the customer we would need to wait for the system to fully thaw before running it and making sure everything was working. System not operational due to the heat pump still having ice build up.

Isaiah C.

Isaiah C. Job Checkin

Upon arrival, I found the heat pump was covered in ice and is unable to be worked on. I quoted the customer a new defrost sensor so they could think about it and informed them to contact us again when the ice had thawed.

Upon arrival, I found the heat pump was covered in ice and is unable to be worked on. I quoted the customer a new defrost sensor so they could think about it and informed them to contact us again when the ice had thawed.

Adam  S.

Adam S. Job Checkin

I installed a new Carrier 3 Ton Electric Furnace / Fan Coil, Carrier 14 SEER 3 Ton Heat Pump,

I installed a new  Carrier 3 Ton Electric Furnace / Fan Coil, Carrier 14 SEER 3 Ton Heat Pump,

Isaiah C.

Isaiah C. Job Checkin

The 2015 Rheem System is in a vacuum indicating that we have a massive leak somewhere that is allowing the compressor to suck in outside air. There is no refrigerant left in this system and this does also mean that the AC compressor could potentially be have been “compressing” none compressables.

The 2015 Rheem System is in a vacuum indicating that we have a massive leak somewhere that is allowing the compressor to suck in outside air. There is no refrigerant left in this system and this does also mean that the AC compressor could potentially be have been “compressing” none compressables.

Isaiah C.

Isaiah C. Job Checkin

Arrived on site customer says the outdoor Carrier system won’t turn on kept house real cool up till yesterday. He replaced the fuses in out door disconnect then called us. Thermostat is calling for cooling have 238v have 23v across contactor. Contactor should be Pulled in and turning system on. Contactor has failed at this time needs to be replaced for the system to turn on. Customer approved wired in new one system came back on. Gauged up to system to check pressures 70/240 4 degrees superheat system is functioning very well

Arrived on site customer says the outdoor Carrier system won’t turn on kept house real cool up till yesterday. He replaced the fuses in out door disconnect then called us. Thermostat is calling for cooling have 238v have 23v across contactor. Contactor should be Pulled in and turning system on. Contactor has failed at this time needs to be replaced for the system to turn on. Customer approved wired in new one system came back on. Gauged up to system to check pressures 70/240 4 degrees superheat system is functioning very well