Lucas M.

Lucas M. Job Checkin

Upon arrival I completed a Half Install of a Annual Spring Air Conditioner Sale Five Star 13 SEER Air Conditioner System Complete (Up to 3 Ton). The system is operational upon departure.

Upon arrival I completed a Half Install of a Annual Spring Air Conditioner Sale Five Star 13 SEER Air Conditioner System Complete (Up to 3 Ton). The system is operational upon departure.

Lucas M.

Lucas M. Job Checkin

Upon arrival I completed a Half Install of a Five Star 80% Gas Furnace (Up to 100,000 BTU). The system is operational upon departure.

Upon arrival I completed a Half Install of a Five Star 80% Gas Furnace (Up to 100,000 BTU). The system is operational upon departure.

Haidar H.

Haidar H. Job Checkin

I completed diagnostics and found the system low on R22 and that it has a leak; I gave the customer his options; repair/ replace.


Jason A.

Jason A. Job Checkin

I gave an estimate to replace a ICP gas furnace and air conditioner. I recommend replacing it with a Carrier 96% 80,000 BTU Gas Furnace and Carrier 13 SEER 3.5 Ton Air Conditioner. Included in the estimate is a 1 year free service maintenance agreement.


Lucas M.

Lucas M. Job Checkin

I installed a Carrier 96% 80,000 BTU Gas Furnace and removed a 2006 Bryant gas furnace. All readings are within manufacturers specifications at this time.

I installed a Carrier 96% 80,000 BTU Gas Furnace and removed a 2006 Bryant gas furnace. All readings are within manufacturers specifications at this time.

Isaiah C.

Isaiah C. Job Checkin

Upon inspection, I found the inducer motor had failed and needed replaced. I informed the customer and they approved the replacement. I will have the office order part and will come back out to install once the part comes in.

Upon inspection, I found the inducer motor had failed and needed replaced. I informed the customer and they approved the replacement. I will have the office order part and will come back out to install once the part comes in.

Adam  S.

Adam S. Job Checkin

I installed a Carrier 96% 80,000 BTU Gas Furnace and a Carrier 15 SEER 3.5 Ton Heat Pump. Everything is operating within manufacturers specifications at this time.

I installed a Carrier 96% 80,000 BTU Gas Furnace and a Carrier 15 SEER 3.5 Ton Heat Pump. Everything is operating within manufacturers specifications at this time.

Isaiah C.

Isaiah C. Job Checkin

I provided an estimate on a Five Star 13 SEER 4 Ton Air Conditioner to replace the customer's current system.

I provided an estimate on a Five Star 13 SEER 4 Ton Air Conditioner to replace the customer's current system.

Isaiah C.

Isaiah C. Job Checkin

I found the noise was the return drop popping. I added an s lock to brace the part. The noise can not be heard anymore. System is operational upon departure.

I found the noise was the return drop popping. I added an s lock to brace the part. The noise can not be heard anymore. System is operational upon departure.

Isaiah C.

Isaiah C. Job Checkin

I found the heat exchanger compromised and in need of replacement. I quoted the price of the repair to the customer, and also recommended they replace the unit due to age and other issues I found with the furnace. Customer will take time to consider options.

I found the heat exchanger compromised and in need of replacement. I quoted the price of the repair to the customer, and also recommended they replace the unit due to age and other issues I found with the furnace. Customer will take time to consider options.

Isaiah C.

Isaiah C. Job Checkin

I was searching for a leak in the refrigerant line and was unable to find it. I ended up replacing both of the schrader valves and tested the system. System checked out fine.

I was searching for a leak in the refrigerant line and was unable to find it. I ended up replacing both of the schrader valves and tested the system. System checked out fine.

Isaiah C.

Isaiah C. Job Checkin

I was searching for a leak in the refrigerant line and was unable to find it. I ended up replacing both of the schrader valves and tested the system. System checked out fine.

I was searching for a leak in the refrigerant line and was unable to find it. I ended up replacing both of the schrader valves and tested the system. System checked out fine.

Isaiah C.

Isaiah C. Job Checkin

I performed a diagnostic on a Carrier electric furnace due to having no heat. Upon arrival customer stated the heat pump is running and shutting off rapidly about every 5 seconds. I checked the heat pump, found system off on low pressure. Weighed in 5 lbs 10 oz of r410a to get the system Running. Suction pressure at 102 which is correct with the current ODAT. Discharge line is 132. Let customer know we will come back and preform a leak search, find the leak and repair it. No cost for repair, system was installed 2 years ago


Haidar H.

Haidar H. Job Checkin

I completed a diagnostic on a Bryant gas furnace. I determined that the furnace exhaust is completely rusted from the inside, the ignitor is ready to crack and the gas valve has water damage. I gave an estimate for repairs. I also gave an estimate to replace the unit. I recommend that due to the age (20 years), condition and cost of repairs that the unit be replaced. The client decided to replace the unit.

I completed a diagnostic on a Bryant gas furnace.  I determined that the furnace exhaust is completely rusted from the inside, the ignitor is ready to crack and the gas valve has water damage.  I gave an estimate for repairs.  I also gave an estimate to replace the unit.  I recommend that due to the age (20 years), condition and cost of repairs that the unit be replaced.  The client decided to replace the unit.

Haidar H.

Haidar H. Job Checkin

I completed a diagnostic on a Bryant gas furnace. I determined that the furnace exhaust is completely rusted from the inside, the ignitor is ready to crack and the gas valve has water damage. I gave an estimate for repairs. I also gave an estimate to replace the unit. I recommend that due to the age (20 years), condition and cost of repairs that the unit be replaced. The client decided to replace the unit.

I completed a diagnostic on a Bryant gas furnace.  I determined that the furnace exhaust is completely rusted from the inside, the ignitor is ready to crack and the gas valve has water damage.  I gave an estimate for repairs.  I also gave an estimate to replace the unit.  I recommend that due to the age (20 years), condition and cost of repairs that the unit be replaced.  The client decided to replace the unit.