Huft has been keeping my heating and air conditioning system in top condition for over a decade. They do a great job.
Customer states water is dripping in the house and from the garage unit. Checked system found condensate pump is working. Checked evaporator drain pan found it drains properly. Found exposed suction line is dripping from the attic. Found outdoor suction line is exposed as well. Found blower wheel to have dirt build up.
Completed and emailed several options for customer to review. Customer will consider options before making final decision.
Performed real-estate inspection. Found condensation line not properly trapped and with no clean out port. No flood switch installed. Recommend installing surge protector on the furnace and Ac units. Furnace gas pressures were high. The low side W.C. was at 2.46 and recommend to be at 1.9 or below. Now set to 1.86. The high side W.C. Was at 3.96 and now is set 3.45. Temp split for furnace is recommend to be 25-55 deg. The temperature split is now 40 deg. The ac unit recommended installing hard start kit. LRA was 122 and manufacture recommends 112. Unit is also low on refrigerant only has a 16 deg split and should have a 20 degree split. Signed up for super hero membership today
Performed Annual Heating Inspection and tune up on Amana Split System. Replaced the filter today. System is operating and heat properly at this time. One more visit for the AC Inspection and tune up.