10103 Iron Rock Way
Elk Grove, CA 95624
833-569-0301

Local Reviews
for north highlands, ca

Rated 5.0 out of 5 stars based on 6 customer reviews

Great Service

Fidel was a very informative technician. Friendly and transparent.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

Very knowledgeable and excellent customer service.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service, very professional!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great service

I really appreciate the professional manor in which Chris took care of a routine checkup on my new H&A unit. He was on the roof for at least 30 minutes in 100* weather. Good job!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Great Service

I love the professional service and quality products!

  • Overall Experience
  • Quality
  • Price
  • Convenience

Got the info I needed

I feel like I understand my A/C more than ever before.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for north highlands, ca

Phong T.

Phong T. Job Checkin

Performed Heat tune up on a 2019 York Heatpump. Door room to air handler are blocking air flow, suggest closing door to improve airflow. Refrigerant level improve from 311/66 to 340/84 and temperature split improve from 20 to 29. Possible air flow and refrigerant issue, advise to get system check out during warmer temperature. Vacuumed blower compartment, filter is good, and cleared drain lines. Heat tune up complete.


Phong T.

Phong T. Job Checkin

Performed diagnostic on a 2013 carrier gas package and found pressure switch stuck. Clear debris on hoses and port, heavy storm two nights prior may cause blockage. System is operational. Found low voltage wirings insulation at unit were breaking off, band aid it with electrical taping, recommend to replace low voltage wirings.


Chris M.

Chris M. Job Checkin

Performed sidekick visit. Completed heating and AC inspection and tune up on Carrier heat pump package unit on roof. System is operating properly at this time.


Alexander D.

Alexander D. Job Checkin

Remove and dispose of old HVAC system Install new 2Ton Rheem Gas/Electric Package unit on roof. Install new drop in curb Install 16x25 return can with 16x25 High Flow Grille. 16in return duct connect to existing Ductwork New Gas Flex and sediment trap New Condensation Drain line Tape and seal duct registers New Service disconnect and electrical whip Install Nest thermostat, I left behind.


octavior@hufthomeservices.com

octavior@hufthomeservices.com Job Checkin

All fixtures and drains in house all working properly. Camera inspected main line found clay pipe from house to the city, line was clear. Found water main from meter to the house, most likely galvanized pipes. Found minimal leak from ball valve to union and found rust and dampness coming from base. Water heater still functioning but due to age recommend replacing with newer model.


Shuntavious  O.

Shuntavious O. Job Checkin

Preformed real estate inspection found the blower motor leaking oil and wheel needs to be cleaned flame sensor needs to be cleaned system has no hard start kit and no surge protection system need to be properly maintained system is operational at this time


Chris I.

Chris I. Job Checkin

Customer request superhero heating inspection service performed superhero heating inspection service removed inspected and cleaned flame sensor adjusted gas pressure to 3.5 inches of water column found system operate properly with a 43 heat rise Inspected system in cooling mode found system operates properly in cooling mode refrigerant level is OK at this time When inspecting filter found a large amount of insulation stuck in the filter inspected return ductwork did not see any obvious breaches system was just installed and this is the first maintenance suspect some insulation may have gotten into the duct during installation advised customer that we will recheck next maintenance During attic inspection found overall insulation level at or below advise customer to look into Having a insulation specialist from Huft come out and perform a quote for getting more insulation added or replaced.


Fidel G.

Fidel G. Job Checkin

Sold HVAC Replacement Rooftop Rheem 2.5Ton Gas/Electric Package. New curb drop in Paid by Service Finance.


Ryan M.

Ryan M. Job Checkin

System non op on arrival. Old tstat was installed and wired correctly, old electric only furnace on a modular home. Tstat was sending power for W to energize. Found all correct voltage and all fuses ok. Found sequencer properly sending voltage to heat strips. Electric heat strips receiving proper voltage but have failed. High potential where they are no longer manufactured. Client to contact home warranty to see if they will help them out, system left non op. Suggested looking into system replacement options.


Fidel G.

Fidel G. Job Checkin

Upon arrival water Heater not working properly, no lit. Cleaned off thermal couple and flame sense Relit pilot and the water heater kicked on Noticed water rust from leak and water heater knocking. Evidence for water heater failure. Recommendations New Water Heater.


Alex  M.

Alex M. Job Checkin

No quote


Jet C.

Jet C. Job Checkin

Found battery terminals on thermostat wasn’t touching batteries. Terminals also has corrosion. Bent terminals to contact with batter. Thermostat is operational at this time.


Shuntavious  O.

Shuntavious O. Job Checkin

Diag preformed on a Goodman system System was locked out on high limit I checked the filter, was extremely dirty client did not have replacement filter I reset system without filter system is operational at this time told client to replace filter ASAP 16x24x1 also client Join the guardian club membership today


Shuntavious  O.

Shuntavious O. Job Checkin

Diag preformed on a carrier system Upon arrival client said system would run but cut off I checked clients filter it was dirty washed filter checked system red light LED was Flashing four times which means limit switch tripped four times reset system let system run inducer motor is making grinding sound but not over amping limit switch did not trip after filter was washed system is operational at this time ordering a box of 20x25x1 merv 13 shipping to client


Glenn R.

Glenn R. Job Checkin

Quoted new heating and air conditioning system.