This is Heidi Gross, real estate broker for David, the property owner. After Ryan's initial inspection of the furnace we received a very reasonable estimate to repair. Everything was ordered and scheduled swiftly. Again, Ryan gave me a courtesy call ahead of our scheduled time, arrived on time, kept me informed of every step involved in the repairs, very professional and courteous. I will certainly use them again for any HVAC inspection/maintenance/repair issues.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Outstanding Service!

I had to schedule an inspection on short notice around the holidays and Huft Home Services was there for me! Ryan gave me a courtesy call ahead of our scheduled time, arrived on time and was extremely courtesy and professional.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for plumas lake, ca

Fidel G.

Fidel G. Job Checkin

Tested and checked all components -No filters replaced at this time, 3 Filters for HVAC. -No gas leaks -37 degrees temperature rise -Tightened all low and high voltage wiring -Performed safety inspection on Heat Exchanger; No areas of concern at this time, has thermal stress but is safe to operate. -Evaporator Coil inspected for restricted air, light dust build up -Indoor Blower motor Amps 8.40A out of 11.80A Max -Cleared Inducer port -Cleaned Ignition assembly -Hot Surface Igniter started to develop Heat stress (White marks), keep an eye on it. -Primary circuit Board okay at this time -Inducer Assembly amp draw 1.68A out of 1.70A Max, making a faint grinding sounds as if bearings are going out. (future repair) HVAC operational at this time. Call Complete.


Ryan M.

Ryan M. Job Checkin

Replace blower motor leaking excessive oil and run capacitor testing below tolerance. Clean and disinfect blower motor wheel, housing and cabinet. Clean ignition components, burners, orfices and flame sensor. Cleaned off platform, wiped down exterior of equipment. Ran and tested heat cycle. System operational.


Andre B.

Andre B. Job Checkin

Upon arrival homeowner stated that furnace would not turn on when calling for heating. Found inducer motor wire has rubbed off from touching inducer wheel. Repaired wiring and tested system operations. System came on with no issues, let system run for 15 minutes and no issues occurred. System is operational at this time.


Ryan M.

Ryan M. Job Checkin

System operational upon arrival. Performed safety inspection on 16 year old Carrier Split Gas Electric Furnace located in attic. No gas leaks detected, checked all electrical connections. Pulled blower motor and housing and inspected heat exchanger, previous company stated eyelids were cracked, this furnace is a serpentine heat exchanger and does not have eyelids, heat exchanger is in poor condition but no visible breaches or cracks at this time. Blower motor leaking excessive oil at top and bottom seal, run capacitor tests below spec and should be replaced. Blower motor wheel and housing should be cleaned. Inducer draft motor fla within spec 1.4/.6A, motor bearings making slight grinding noise on start up. Ignition components have not been cleaned in a long time. System is operational.


Kris D.

Kris D. Job Checkin

Lennox ML14XC1/ML180E - Removed and properly dispose of existing gas/electric unit, provide and install new 4.ton multi-stage gas/electric split horizontal in attic, 30x20 & 14x14 ceiling high flow grille, connecting to existing filters, Honeywell T-6 thermostat, a/c pad, disconnect/whip, gas flex connector/shut off valve, flushing existing drains/refrigerant lines, connecting to existing drains/refrigerant lines and ducting, installation includes equipment, material, permit, title 24, third party verification and taxes. ML14XC1- Single Stage Air Conditioner ML180E- Single Stage Furnace ADP Coil to match Honeywell T6 Thermostat 16 SEER/80% AFUE Built to perform and help to save energy. With efficiencies of up to 16 SEER, this system will help save you hundreds of dollars per year in energy bills, compared to your older air conditioner. 10 Year Parts/2 Year Labor 20 Year Heat Exchanger 1 Year Side Kick Club (1 visit per year) Total installation: 10,710 Method of payment: Service Fi


Timothy  M.

Timothy M. Job Checkin

Found the upsrairs damper not operational. I was able to manually open the ARD 16 damper yo get air flow upstairs zone. Recommend replacing damper.


Chuc N.

Chuc N. Job Checkin

Replaced blower assembly and cycled system. Also signed up for a guardian club. System operations ok at this time


Timothy  M.

Timothy M. Job Checkin

Performed air conditioning diagnostic on 2 year old Goodman split system. Found capacitor on herm side with a 0 reading on my meter when it’s rated at 40/5. Installed new part capacitor. Tested all amp draws after installing new cap.and found the system running within manufacturers recommendation. I recommend a hardstart kit and a club membership.


Larry G.

Larry G. Job Checkin

Performed air conditioning tuneup on carrier split system. Found high amp draws from compressor. Recommended changing duel capacitor and adding a hardstart kit and membership. After installing hardstart kit and capacitor amp draws are lower in manufacturers specifications. System is operational at this time.


Alex  M.

Alex M. Job Checkin

Emailed several options and customer will go over proposal with husband tomorrow before making final decision.


Andre B.

Andre B. Job Checkin

Performed ac tune for York split system. Tested and checked system in cooling mode. Checked all safeties and connections. Washed filters. Sealed air leaks on furnace. Told homeowner not to run heating due to flue pipe being disconnected from system. System is operational with issues at this time.