10103 Iron Rock Way
Elk Grove, CA 95624
833-569-0301

Local Reviews
for pollock pines, ca

Rated 5.0 out of 5 stars based on 4 customer reviews

Great and quick service

  • Overall Experience
  • Quality
  • Price
  • Convenience

Working out the kinks

We bought a whole house humidifier along with our new heat and A/C system. The humidifier wasn’t working after the install and Mr Oliver did everything he could go track down the issue and ordered the parts to get it working. Expect they will be back soon.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Quick response

  • Overall Experience
  • Quality
  • Price
  • Convenience

Very sophisticated.

Knowledgeable, professional, courteous, and affable.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for pollock pines, ca

Miguel R.

Miguel R. Job Checkin

Diagnostic call for no heat on a 10 year old Bryant gas furnace located underneath the home. Upon arrival system was non operational. LED diagnostic flash code displaying code no no flame sensed and then goes into lockout. Checked system and realized the burner assembly, the flame sensor, and the igniter were improperly installed. Burner assembly was upside down plus the igniter and flame sensor were backwards in terms of placement of which burner they were supposed to be in front of. Rearranged burner assembly and sensors and cycled system multiple times without any problems. System is operational and heating at this time. Signed homeowner up for superhero club membership. No diagnostic charge for today. Will have 2 visits after today


Shuntavious  O.

Shuntavious O. Job Checkin

Going to send someone back out to tap into the the hot water line under the house. Need to seal around board by the condenser unit that we added Humidifier is operational at this time


Bradley M.

Bradley M. Job Checkin

Replaced pressure switch assembly on amana system. Tested. System is operational at this time. Performed courtesy checks on both furnaces. Amana system. Cleaned flame sensor. Checked igniter. Tightened wiring connections. Inducer and blower motor are operating within manufacturer specs. Am. Std. System. Tested heat. Checked flame sensor and igniter. Tightened wiring connections. Inducer and blower motor are operational. Both capacitors are within spec. System is operational at this time.


Bradley M.

Bradley M. Job Checkin

Replace pressure switch to allow for proper unit operation. Will have to order switch. Signed up on club membership (2 system) for routine maintenance and savings.


Shuntavious  O.

Shuntavious O. Job Checkin

Replace humidifier check system after repair is operational at this time


Shuntavious  O.

Shuntavious O. Job Checkin

Checked Humidifier it is not working at this time ordering current sensory relay and also ordering a new automatic control for the humidifier also supply registers need to be sealed and we need to add dampers to the system


Alexander D.

Alexander D. Job Checkin

Remove and Demo existing package unit and haul away. Install Lennox 4 Ton 14.0 SEER/96% Furnace (1 Stage). install and run new condensate line to exterior and verify flow. Install new electrical dis-connect at condenser with properly sized fuses and weather tight flexible whip. Furnish and install new 7/8 “ refrigerant line from condensate pad to basement location of new AC Coil. Re-position new Furnace and AC coil in basement using hung-rite hardware ( To be hung from exposed floor joists.) Re-connect existing ductwork and add new runs as required in basement with new R8 Mylar coated flex duct. Install new return/Supply plenum and Include new hi flow registers (2nd floor only) and manual dampers (Remove downstairs registers, manually seal boots and re-install existing floor registers. Install homeowner supplied Thermastat. Install new 5 inch filter tray in line with furnace with new MERV 13 filter. HERS certification includes third party duct pressure test. Installation include


Kris D.

Kris D. Job Checkin

Gave price on 4 Ton Rheem and converting from package unit on ground to split system in basement


Miguel R.

Miguel R. Job Checkin

Upon arrival system was off. Set to heat. Inducer comes on and spark igniter sparks but no ignition. Gas valve is getting proper voltage. Hit gas valve as it got voltage to open and system ignited. Gas valve is sticking and should be replaced. Checked electrical, blower capacitor is out of spec. Recommend replacing. Performed courtesy safety inspection due to age of system. Heat exchanger is beginning to crack behind faceplate. Recommend upgrading system due to age (26 years old), efficiency, and cost of repairs. Set up appointment for system replacement for November 10th at 11am. System is intermittently operational


Kris D.

Kris D. Job Checkin

3 Ton Rheem $7,500 Up/Horiz. Replace existing split system with a Rheem Single Stage split system with Energy Star Condenser. Install Honeywell T6 Pro thermostat. Run new 220V circuit to new condenser location. Run new refrigeration lines from condenser to evaporative coil. Run new primary condensate drain. Cut in new 12” Silver-Jacketed Return Air to a 10” X 20” sidewall High Flow Grill behind the front door. Replace existing 20” X 20” Return grill with a High Flow Grill. Replace flue pipe. Installation includes: Installation by HUFT Journeyman employees, all Comfort Guarantees, remove and dispose of existing equipment, Title 24 HERS certification with a third party including duct leakage test, gas flex with ball type shut off valve, electrical disconnect with properly sized fuses, dispose of existing equipment, weather tight flexible whip at condenser, labor, material, taxes and permits. Rheem: RA1436WJ1NA, R801TA050314MXA, RCF3617STAMCA Efficiencies: 15.1 SEE


Glenn R.

Glenn R. Job Checkin

Quoted $7,500 Special and High Efficiency Furnace.


Glenn R.

Glenn R. Job Checkin

Quoted new Goodman heat pump system.