Ryan H.

Ryan H. Job Checkin

Annual maintenance on a 2016 American standard air conditioner. The system is in great shape and running as efficiently as positive after some routine maintenance. Spoke with the customer about a duct sanitizing and they want to discuss this with their partner.


Ryan H.

Ryan H. Job Checkin

Maintenance call for a 2015 Bryant air conditioner. The system is in good shape at this time. The blower motor capacitor was weak and replaced here today. The evaporator coil is dirty and starting to restrict air flow and the customer is going to get it cleaned at a later date. The LRA was a little over the data plate as well.


Ryan H.

Ryan H. Job Checkin

Service call for a dehumidifier not working. Technician arrived to find the system throwing an e6 code and not on. The system had thrown the code back in the winter time. Cycled power and the system is running fine. Informed the customer to turn the power off to the dehumidifier during the winter.


Ryan H.

Ryan H. Job Checkin

Single system furnace tune up on a 2010 concord. The system is in good shape after some routine repairs replacing a blower motor capacitor.


Ryan H.

Ryan H. Job Checkin

Annual furnace maintenance on a 14 year old Lennox furnace. The thermostat was malfunctioning on the heat side so it was replaced here today. The system is in good shape and ready for the winter months.


Ryan H.

Ryan H. Job Checkin

Service call for an air conditioner not keep up in the afternoons. The technician found the system was low on refrigerant. Got the system charged up here today and will get pricing and availability of the coil replacement on Monday.


Ryan H.

Ryan H. Job Checkin

Single system ac maintenance on a 7 year old American standard. The system is in great shape with all capacitors and electric motors within manufactures specifications. Cleaned the condenser coil to keep the system running as efficiently as possible.


Ryan H.

Ryan H. Job Checkin

Installed a new dehumidifier in the attic to control indoor humidity. Customer had abnormally high humidity causing mold issues.


Ryan H.

Ryan H. Job Checkin

indoor air quality service call for a customer who has extremely high humidity in their home. Did a full system inspection and checked the crawl space to ensure there were no leaks. Gave the customer an option on a whole home dehumidifier.


Chris V.

Chris V. Job Checkin

Single system A/C Maintenance Tune up, 3 Year Old 5 Ton High Efficiency Trane System, Technicians evaluated and Checked all Safety Devices as well as Every Component that is used for Normal Air Condoning operation, The Secondary Drain on the system doesn’t have an SS2 Water Safety switch, An SS2 is a device that will shut the system off if the Primary drain ever backs up, Also One of the Bedrooms are always Hot or Cold Due to lack of ducts to the room, and Customer has allergies within home, Technicians offered several options for Indoor Air Quality to help eliminate any Bacterias, Allergens, Airborne Viruses, As well as Black Substance growth that grow and build up within the HVAC System. Technicians Ran a New Duct Supply Run to the bedroom that was struggling for air, After installation The room feels much better.


Ryan H.

Ryan H. Job Checkin

Service call for a no heat. Technician found a a failed blower motor. Performed furnace repair and replaced the motor, and got our customer back up and going on a Saturday.


Caleb P.

Caleb P. Job Checkin

Found the mini split unit covered in dirt and black substance.recommend a deep cleaning.


Caleb P.

Caleb P. Job Checkin

Service call replaced evaporator coil in sperry Oklahoma

Service call replaced evaporator coil in sperry Oklahoma

Caleb P.

Caleb P. Job Checkin

Service call no cool found unit low on refrigerant in sperry

Service call no cool found unit low on refrigerant in sperry

Caleb P.

Caleb P. Job Checkin

Service call no cool found unit low on refrigerant in sperry

Service call no cool found unit low on refrigerant in sperry