3329 Dove Rd
Port Huron, MI 48060
810-956-8700

Local Reviews
for saint clair, mi

Rated 5.0 out of 5 stars based on 1 customer reviews

toasty on second floor

These guys are very good. And, very professional. They did blown-in insulation, baffles to increase air ciculation, and spray foam in air leaks. This took 2 days, and now the second floor is very toasty.

  • Overall Experience
  • Quality
  • Price
  • Convenience

Job Locations
for saint clair, mi

Ron M.

Ron M. Job Checkin

Insulation Plus installed 4' basement blanket in this new house

Insulation Plus installed 4' basement blanket in this new  house

Ron M.

Ron M. Job Checkin

Insulation Plus installed R-38 in the unaccessable ceiling, and baffles in the soffit area of this new house.

Insulation Plus installed R-38 in the unaccessable ceiling, and baffles in the soffit area of this new house.

Kyle L.

Kyle L. Job Checkin

Kyle and Dwayne performed an R- 21 closed cell foam installation to the exterior walls while Jayden installed R-31 fiberglass to the ceiling of a newly built addition.

Kyle and Dwayne performed an R- 21 closed cell foam installation to the exterior walls while Jayden installed R-31 fiberglass to the ceiling of a newly built addition.

Kyle L.

Kyle L. Job Checkin

Kyle and Jayden performed R-14 closed cell foam to the bond area area and the exterior walls of a remodeled crawl space.

Kyle and Jayden performed R-14 closed cell foam to the bond area area and the exterior walls of a remodeled crawl space.

Kyle L.

Kyle L. Job Checkin

Kyle and Will performed R-10.5 closed cell foam installation to the exterior brick wall and seam of a newly constructed theater.

Kyle and Will performed R-10.5 closed cell foam installation to the exterior brick wall and seam of a newly constructed theater.

Justin F.

Justin F. Job Checkin

Justin performed a blower door efficiency test

Justin performed a blower door efficiency test

Benjamin S.

Benjamin S. Job Checkin

Larry Dewayne and Ben installing r13 wall spray cellulose into garage wall cavities of new construction

Larry Dewayne and Ben installing r13 wall spray cellulose into garage wall cavities of new construction

Benjamin S.

Benjamin S. Job Checkin

Larry Justin and Ben installing r11 fiberglass batts unfaced into exterior wall cavities of existing home basement

Larry Justin and Ben installing r11 fiberglass batts unfaced into exterior wall cavities of existing home basement

Kyle L.

Kyle L. Job Checkin

Tory and Kyle preformed R-21 closed cell foam installation to the roof deck and gable walls of a newly built bonus room.

Tory and Kyle preformed R-21 closed cell foam installation to the roof deck and gable walls of a newly built bonus room.

Tory B.

Tory B. Job Checkin

Tory and Dwayne installed 3” closed cell foam into roof deck and exterior walls of this bonus room


Kyle L.

Kyle L. Job Checkin

Kyle and Will preformed R-21 closed cell foam installation to the exterior walls of the main floor, and one exterior wall in the basement, plus R-19 to the bond area of a newly constructed home.

Kyle and Will preformed R-21 closed cell foam installation to the exterior walls of the main floor, and one exterior wall in the basement, plus R-19 to the bond area of a newly constructed home.

Kyle L.

Kyle L. Job Checkin

Kyle and Will preformed R-21 closed cell foam installation on the exterior walls of a newly constructed house.

Kyle and Will preformed R-21 closed cell foam installation on the exterior walls of a newly constructed house.

Benjamin S.

Benjamin S. Job Checkin

Justin and Ben installing r11 fiberglass batts unfaced into exterior basement walls

Justin and Ben installing r11 fiberglass batts unfaced into exterior basement walls

Benjamin S.

Benjamin S. Job Checkin

Justin and Ben installing r49 blown cellulose insulation into attic of existing home

Justin and Ben installing r49 blown cellulose insulation into attic of existing home

Benjamin S.

Benjamin S. Job Checkin

Larry and Ben installing basement blanket in basement of new construction home