Jason B.

Jason B.


Job Checkin

20JAN2022 Jason B Arrived for for fall tune up. Spoke with Homeowner about systems performance. Cycle system on at thermostat then disconnect power at furnace. Pull blower and coil door, inspect heat exchanger, capacitor and blower motor. Reinstall blower pull and clean flame sensor. Test all pressure switches, then reconnect power. Cycle system on in heating. Adjust gas pressure to 3.5 IWC. Inspect HSI, burners, and all safeties. Check amp draws, inducer, gas manifold, temperature split, and CO Levels. System is running properly at this time. found a lack of attic insulation and undersized ductwork. Attached are quotes please give me a call if you have any questions. -Jason