Joseph K.

Joseph K.


Job Checkin

I arrived for a blue club member no heat noise on a home that is having a roof put on currently. I inspected the system and found large amounts of roofing debris in the induced draft motor housing and inside the cabinet that houses the burner assembly. I disassembled the induced motor assembly and vacuumed out all debris in the housing, burner cabinet, on top of the furnace and in the closet floor. I reassembled the furnace and checked the systems amp draw on the induced draft motor and found it to be running at 1.19-1.25 amps. The amp draw on the motors data plate states that the motor is not designed to run more than 1.20 FLA. ( fan load amps ) There is no abnormal noise to the motor at this time, no damage to the induced motor fan wheel to make it become unbalanced. If any other debris find its way into the motor housing agin shut the system off and we will come inspect and clean the system after the roofers are finished with their job. They were currently worked on the roof at the