9320 S. Pole Rd
Oklahoma City, OK 73160
(405) 794-8900

Our Top Cities


Job Locations
for spencer, ok


Map of Spencer OK
ADAM  R.

ADAM R.


Job Checkin

I came out for a no cool. The said the system was freezing up. I checked the system over and cycled the ac and found the system low on refrigerant. The unit has 407c refrigerant. They’ve had to add refrigerant before. I recommended a to add refrigerant and a leak search. I also discussed system replacement due to the old age and condition of the equipment. They just wanted to add refrigerant today. I added 2lbs of 407c and got the SH to 20 and the system was calling for 21. All working at this time.