Brian L.

Brian L. Job Checkin

Found a leaking Goodman evaporator coil

Found a leaking Goodman evaporator coil

Brian L.

Brian L. Job Checkin

Found a leaking evaporator coil on a Carrier heat pump system


Brian L.

Brian L. Job Checkin

Found a leaking condenser coil on a Carrier system


Brian L.

Brian L. Job Checkin

Found a grounded compressor on a Goodman heat pump system

Found a grounded compressor on a Goodman heat pump system

Brian L.

Brian L. Job Checkin

HVAC Repairs: Upon receiving a service call for a malfunctioning ductless mini-split system, I conducted a thorough inspection. Identifying an issue with the fan blade affecting system efficiency, I meticulously remounted and realigned the fan blade to restore smooth and efficient operation. This meticulous attention to detail ensures optimal performance and longevity of the ductless mini-split system, meeting the client's expectations for reliable climate control in specific zones.


Joe  L.

Joe L. Job Checkin


Robert C.

Robert C. Job Checkin

Performed cooling tune up on on to trane heat pump splits

Performed cooling tune up on on to trane heat pump splits

Amanda G.

Amanda G. Job Checkin

HVAC System Replacement: Confronted with an aging HVAC system causing frequent breakdowns and soaring energy bills, a homeowner opted for a comprehensive solution. We recommended and executed a complete system replacement, incorporating a high-efficiency unit. This upgrade not only improved overall comfort but also significantly reduced energy consumption, translating into substantial long-term cost savings for the homeowner.


Joe  L.

Joe L. Job Checkin

Performed heating maintenance on a Goodman heat pump


Chad R.

Chad R. Job Checkin

Goodman heat pump package unit. Return flex is filling with water. Reason is due to gaps in the rain shield allowing rain water to flow into duct. Quoted to replace damage duct and reseal hood

Goodman heat pump package unit. Return flex is filling with water. Reason is due to gaps in the rain shield allowing rain water to flow into duct. Quoted to replace damage duct and reseal hood

Dilan  G.

Dilan G. Job Checkin

Replaced compressor in goodman heatpump


Shawn  L.

Shawn L. Job Checkin

Replaced a control board on the customers downstairs Goodman heat pump. The system is now running and heating.

Replaced a control board on the customers downstairs Goodman heat pump. The system is now running and heating.

Shawn  L.

Shawn L. Job Checkin


Joe  L.

Joe L. Job Checkin


Joe  L.

Joe L. Job Checkin