Furnace Repair: A client reported that their furnace was not heating efficiently. During my thorough inspection, I checked the heat exchanger for cracks or other damage. Finding it in good condition, I cleaned and fine-tuned the system to restore peak performance. The furnace now operates safely and provides consistent warmth.
Goodman package heat pump, whole house system. performed the heating maintenance at today's visit. checked and tested the heat operation and all components. everything checks well and system is heating well. no issues to report at this time. customer mentioned that at start up, there is a sound that happens, and it will go away a few moments later. I tested everything and found no issues. the sound that is being heard is the compressor when it starts.
HVAC Repair: The client reported loud noises and vibrations coming from their HVAC system. Upon inspecting the system, I found that the blower motor bearings had worn out, causing excessive noise and inefficient operation. I replaced the bearings, restoring the system’s quiet, smooth performance.
Heating System Repairs: The client reported inconsistent heating and unusual smells coming from the furnace. Upon inspection, I found a cracked heat exchanger that posed both efficiency and safety risks. Replacing the damaged heat exchanger restored the system’s proper heating performance, ensuring safety and warmth as autumn set in.
performing a heating maintenance on a Gibson heat pump system
Air Duct Sealing: Sealed air duct leaks to improve HVAC efficiency, reduce energy costs, and enhance home comfort.
Air Conditioning System Repair Service: Investigated and resolved a client's AC blowing warm air issue by replenishing refrigerant levels and sealing leaks. Discussed maintenance plans for sustained performance.
downstairs back area, heat pump split. at arrival, found a failed capacitor that was keeping the outdoor unit from operating properly. replaced capacitor and tested and system is now cooling very well.
upstairs American standard split heat pump. at arrival, found that the outdoor fan wouldn't not start. reason for this was due to a bad capacitor. replaced the capacitor and tested and the system is now cooling very well.
outdoor unit had a failed capacitor that was keeping it from turning on. replaced the capacitor and tested. system is now cooling as it should. attached a quote for our HVAC Protection Pledge to clean and maintain the system for best performance
chemically cleaned the condenser coils. Then added freon to this Trane system