Drew R.

Drew R. Job Checkin

Performed clean and check on AC system. Checked refrigerant charge, superheat and delta-T. Tested and inspected all electrical components and blower motor assembly, checked filter which does not need changed, ensured proper drainage, tested t-stat operations and cycled system in cooling. Advised customer that blower capacitor is getting weak, recommended replacing. Customer will be interested in equipment replacement estimate sometime soon. Everything is operating normally at this time.


Nathan  R.

Nathan R. Job Checkin

Found unit flow on charge installed stop leak and added 3 pounds of R22 cycle system all operation are okay at this time


Bill  V.

Bill V. Job Checkin

Found bad connection at start cap repaired


Nathan  R.

Nathan R. Job Checkin

Performed winter maintenance, cycled all equipment, ran all tests needed, tested all safety devices, found units to be working within specification, all operations ok at this time. Spoke about adding exhaust fans in the warehouse area to solve the c High carbon monoxide levels in the offices.


Ray B.

Ray B. Job Checkin

Found they had both furnaces shut off for a couple days but still showing high levels of carbon monoxide in the office area, found the carbon monoxide to be coming from the warehouse area and sucked into the offices, explained they may have to run the fans on the furnaces to pressurize the offices to help keep it out or better exhaust the warehouse area, furnace operations ok at this time.


Ray B.

Ray B. Job Checkin

Found they had both furnaces shut off for a couple days but still showing high levels of carbon monoxide in the office area, found the carbon monoxide to be coming from the warehouse area and sucked into the offices, explained they may have to run the fans on the furnaces to pressurize the offices to help keep it out or better exhaust the warehouse area, furnace operations ok at this time.


Nathan  R.

Nathan R. Job Checkin

Found two unit heater not working 1 of the heaters had a bad pressure switch. replaced pressure switch. The other unit heater had bad thermocouple and the pilot assembles was dirty and clogged. Cleaned pilot assembley and replaced thermocouple cycled systems all operation are okay at this time