Found breaker stuck closed on heat pack, ordered new heat pack and breaker returned and installed performed clean and check for winter all operations are normal at this time.


Nathan  R.

Nathan R. Job Checkin

Found pool heater with a bad thermal cut off switch ordered new switch will return to replace once it comes in. Returned on 7/24 replaced thermal cut off swith cycled heater all operations are OK at this time.


Nick H.

Nick H. Job Checkin

found bad split capacitor and replaced reset lockout cycled ac checked refrigerant and filter all operations are normal at this time.


Drew R.

Drew R. Job Checkin

Performed clean and check on AC system. Checked refrigerant charge and superheat, tested all electrical components, cleaned condenser coil, checked condensate drain, changed filter that customer provided, measured delta T, tested t-stat operations, cycled system in cooling. Found weak blower capacitor leaking oil.


Nick H.

Nick H. Job Checkin

Started heat pump in cooling mode condensor fan motor did not turn and system immediately went into high pressure shut down system tested and inspected electrical components and control found rodents nest in defrost board and capacitor removed nedt tested board which was good tested capacitor found capacitor was weak on compressor side and failed on fan side replaced capacitor at this point fan motor had cooled off cycled unit in cooling checked temp drop and charge with blanket added due to outdoor temp tested in heat pump heating checked heat rise all operations are normal at this time.


Nick H.

Nick H. Job Checkin

Performed clean and check on ac and renewed customer contract.


Bill  V.

Bill V. Job Checkin

Arrived at customers home to a no heat call on a 1985 Grand gas furnace. Called Grand and parts to fix the furnace are no longer available. Furnace shoeing signs of cracked heat exchanger. So furnace condemned.


Nick H.

Nick H. Job Checkin

Customer had a very clogged filter which had caused the unit to freeze up and leak into the return. Filter was changed at last service did not heavy dust through out the furnace and laundry room. Recommended we perform winter maintenance as they were due performed maintenance on heat pump heating and electric furnace. Tested and inspected all electrical components and controls confirmed proper operation of the defrost cycle, checked heat rise in heat pump and electric back up checked amp draws on each heat bank, added cleaning agent to condensate pump and confirmed proper operation no issues besides airflow from the clogged filter which I removed. Informed customer that if they see water from the unit to always check the filter first.


Nick H.

Nick H. Job Checkin

Found small amounts of water in the return, float switch had not activated on condensate pump and pump water level was normal, checked trap confirmed unit was draining properly cycled system Checked charge and airflow which was normal inspected coil and air handler found insulation peeling from the cabinet which I removed this may have occured at time of last service but could not be sure as there was no leak present at time of inspection.


Nick H.

Nick H. Job Checkin

Found float switch working intermently replaced pump and subtracted price from servicing the pump on last service call tested tied wet to furnace all operations are normal at this time.


Nick H.

Nick H. Job Checkin

Found condensate pump clogged cleaned pump and drain line performed cnc on a.c. system all operations are normal at this time.


Ray B.

Ray B. Job Checkin

Found unit low on R22 refrigerant, balanced system with 2 pounds of R22, cycled unit, all operations ok at this time.


Nick H.

Nick H. Job Checkin

Found breaker tripped reset breaker both h.v. fuses were blown which I replaced attempted to start unit fan engaged compressor attempted to start however is locked up which blew the fuses informed customer of my findings recommend the customer replace the unit due to the age and condition. Scheduled for Greg to come out and give a qoute for a new system.


Nick H.

Nick H. Job Checkin

Checked all electrical components and controls checked filter added cleaning agent To condensate pump found drain for a coil was nearly clogged which I cleared and added bleach to trap all operations are normal at this time.


Ray B.

Ray B. Job Checkin

Found furnace with a bad high limit switch, customer ordering one and fixing it themselves, furnace not operating currently.